Wiring for controlling electrical equipment and instrument meters, monitoring and controlling return circuit, protecting and measuring in power distribution with rated voltage up to 450/750V(0.6/1KV) A.C.
Standards
GB/T9330-2008 ,IEC 60502, etc.
*We can also design and produce for special application requirement.
Operating features
3.1. The maximum permissible continuous operating temperature is 70℃
3.2. The lowest installation temperature of the cable is 0℃ .
3.3. Permissible Min. Bending radius not less than 6 times of the completed cable diameter for unarmoured cable; not less than 12 times of the completed cable diameter for armoured or copper tape screened cable; not less than 6 times of the completed cable diameter for screened flexible cable.
Type, descriptions and applications
Chinese Type | Descriptions | Applications |
KVV |
Copper conductor PVC insulated PVC sheathed control cables |
For laying indoor, in tunnels, ducts, conduit etc.permanent place |
KVVR |
Copper conductor PVC insulated and sheathed flexible control cable |
For laying indoor ,in tunnels, ducts and movable using |
KVVP |
Copper conductor PVC insulated and sheathed copper wire braiding shielded control cable |
For laying indoor, in tunnels, ducts, conduit etc. permanent place where shield required. |
KVVRP |
Copper conductor PVC insulated and sheathed copper wire braiding shielded flexible control cable |
For laying indoor ,in tunnels, ducts and flexible and shield required etc.place ,easy to move |
KVVP2 |
Copper conductor PVC insulated PVC sheathed copper tape shielded control cables |
For laying indoor, in tunnels, ducts, conduit etc. permanent place where shield required. |
KVVP2-22 |
Copper conductor PVC Insulated PVC Sheathed Copper Tape shielded steel tape armored Control Cables |
Used in light-current control system and heavy-current magnetic interference region. |
KVV22 |
Copper conductor PVC insulated PVC sheathed steel tape armored control cables |
For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force |
KVV32 |
Copper conductor PVC insulated PVC sheathed steel wire armored control cables |
For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force |
Production range
Type |
Rated voltage U0/U |
Nominal conductor cross section (mm2) | Standards | |||||||
0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | ||||
Number of cores | ||||||||||
KVV | 450/750V | 2~61 | 2~14 | 2~10 | GB/T9330-2008 | |||||
KVVR KVVRP | 2~61 | - | - | |||||||
KVVP2 KVVP | 4~61 | 4~14 | 4~10 | |||||||
KVV22,KVV32, KVVP2-22 | 7~61 | 4~61 | 4~14 | 4~10 |
Note: Recommended core numbers are 2,3,4,5,7,8,10,12,14,49,24,27,30,37and 61